The Sherpa Guide Series

Data Center Development

Nordics Edition · 2026

How to take a site from raw land to an energized, leased facility — what to do, in what order, and what it costs you when you get it wrong.

Data Center Development cover
Type
Guide
Extent
215 pages
Published
August 2026
Geography
SwedenNorwayFinlandDenmark Nordics
Publisher
Global Infrastructure Sherpa / Sherpa Publishing
Price
$995 — single-user licence

Overview

This is a working document, not a market report. It assumes you are trying to actually build something.

Most data center publications tell you how big the market is. That is a number you can get for free, and it will not help you. This guide tells you what to do, in what order, and what happens when you do it in the wrong order — which, in this business, is usually fatal to the schedule and occasionally fatal to the project.

One organising idea runs through it. Data center development used to be a real estate business with an electrical problem attached. It is now an electricity business with a real estate problem attached. Every sequencing recommendation here follows from that inversion: you do not select a site and then find power. You find power and then select a site.

Four countries throughout — Sweden, Norway, Finland and Denmark, with Iceland in short — because the physics is universal but the regulation is not, and the regulation is what will hurt you.

What this guide covers

Sixteen parts covering the full development sequence — the map of who does what, choosing your game, site selection, securing power, permitting and politics, design and delivery, the capital stack, offtake and leasing, exit, pitfalls, a 100 MW worked example from first enquiry to commercial operation, life after the building, and the chapters most publications leave out: electricity taxation and incentives, signing the build, physical security and waste heat. Closes with a five-page tear-out field checklist, an indicative Nordic timeline, a glossary and a full index.

Who this is for

Developers, investors, lenders and operators taking a Nordic data center site from raw land to an energized, leased facility.

What you get

  • Practical development guidance, not market sizing
  • Deal Evidence — real, public transactions that demonstrate each point
  • What This Costs You — the schedule and budget consequence of each common mistake
  • Best Practices — the distilled instruction set for each stage
  • Ask Before You Sign — questions to put to the counterparty before you commit
  • A 100 MW worked example, from first enquiry to commercial operation
  • Four countries throughout: Sweden, Norway, Finland and Denmark, with Iceland in short
  • Chapters most publications leave out: electricity taxation, build contracts, physical security and waste heat
  • A five-page tear-out field checklist, a full index and 814 numbered references

Table of contents

  1. How to use this guide
  2. Part 0 — The Map: Who does what, and where the money is actually made
  3. Part 1 — Choosing Your Game: What the building is for, and which business you are really in
  4. Part 2 — Site Selection: Bid zone first, everything else second
  5. Part 3 — Securing Power: Bid zones, connection queues and the transmission constraint
  6. Part 4 — Permitting and Politics: Planning, environment, and the licence to operate
  7. Part 5 — Design and Delivery: Who to hire, when, and how the building actually gets built
  8. Part 6 — The Capital Stack: Who funds what, and what they need to see first
  9. Part 7 — Offtake, Leasing and Marketing: Getting on the list, and getting the lease signed
  10. Part 8 — Exit: Sell, hold, refinance or recapitalise
  11. Part 9 — Pitfalls: Twelve strategic and tactical ways this goes wrong
  12. Part 10 — The Worked Example: One site, from first phone call to commercial operation
  13. Part 11 — After the Building: Handover, operations and insurance
  14. Part 12 — Electricity Taxation and Incentives: The rate you underwrite, and the risk that it moves
  15. Part 13 — Signing the Build: The clauses that decide who pays when the transformer is late
  16. Part 14 — Physical Security: Standards, tenants, and what you cannot retrofit
  17. Part 15 — Waste Heat: The second revenue line that does not exist elsewhere
  18. The Field Checklist: Tear-out — five pages, everything that matters
  19. Appendices — Reference: An indicative Nordic timeline · Glossary · On sources · Index · Sources and references

Research and sources

Material factual figures carry a source and an "as of" date. Practitioner assumptions and constructed estimates are identified as such rather than presented as measured fact. Where a widely circulated number could not be traced to a published authority it is labelled as convention or omitted, and the omission is noted.